Marine Equipment »   
     
   
   
   
   
   
   
   
   
  Specifications
   
 
Fueling Stations
General Specifications – Gemini/GE Compressors


Fueling Stations

The Strauhs CNG fueling stations are compact units, consisting of a compressor unit installed on a metallic structure (skid), containing all the elements necessary for compression, storage and distribution of the gas.

• Direct coupling (without belts)
• Air-gas refrigeration
• Electrical motor drive
• 3 or 4 stage compression
• Explosion-proof and intrinsically safe electrical installation
• Simple and compact design
• Low maintenance
• High performance and reliability
• Electrical panel controlled by PLC
• Suction and discharge filters assure low levels of oil in the gas supply
• Sound insulation enclosure and protection against weather

Compressors

Gemini compressors are known and respected throughout the world for their quality and durability. They are one of the leaders in the market for gas compression, with more than 10,000 compressors installed. Designed to attend to the most varied applications, the Gemini alternative compressors are available in the widest range of power settings, flows and suction and discharge pressures.

• Horizontal alternative compressors, for up to 4 stages of compression;
• High resistance structure designed for the highest loads and to guarantee a long useful life;
• Balanced compressor cylinders minimize vibration;
• Reliable and of simple maintenance, making for very low service down time;
• Designed for heavy and continuous operations, the compressors are all tested before leaving the factory.

Storage Cylinders

Consist of a set of interconnected cylinders mounted on a metallic structure.

• Various sizes and configurations available
• Certified cylinders
• Safety valve
• Pressure Gauge
• Excess flow valves
• Hydrostatically tested to 375 barg

Control Panel

Consists of a steel panel for installation in a non-risk area containing all the elements for the control, monitoring and safety of all the compressor functions.

• Programmable Logic Control (PLC)
• Optional remote communication via modem
• Motor action by "soft-starter"
• Explosion-proof and intrinsically safe electrical installation
• Auto-monitoring of safety of all compressor functions
• Indication on PLC display of compressor operation and
  alarm messages

Sound and Weather Protection Enclosure

The enclosures provide protection against the weather and attenuate the noise generated by the compressor, maintaining them within the limits suitable for installation in urban areas.

• Sound insulation
• Weather protection
• Built in high resistance steel structure
• External instruments panel
• Doors on all sides for ease of maintenance
• Gas detector at one point with alarm (optional)
• Lifting rings
• Adequate internal space to carry out maintenance
• Internal explosion-proof lighting

Fueling Stations
General Specifications – Hurricane Compressors


Fueling Stations

The Strauhs CNG fueling stations are compact units, consisting of a compressor unit installed on a metallic structure (skid), containing all the elements necessary for compression, storage and distribution of the gas.

• Hurricane compressors
• Air-gas refrigeration
• Lubricated cylinders
• Electrical motor drive (50hp)
• Explosion-proof and intrinsically safe electrical installation
• Simple and compact design
• Low maintenance
• High performance and reliability
• Electrical panel controlled by CLP
• Sound insulation enclosure and protection against weather.
• Dimensions:
                  Length: 1,6m
                  Width: 1,6m
                  Height: 2,0m


Compressors

The Hurricane compressors are manufactured in North-America, designed to work exclusively with CNG. They supply flows of up to 127 Nm3/h, and are ideal for supplying fork-lift trucks or for fleets of vehicles. They operate with low suction pressures of up to 0.9 barg, and are thus the ideal choice for use in factories, where the pressures available are generally of this order. Hundreds of units are in operation in the USA.

• 4 stage compression;
• Belt drive;
• Lubricated cylinders;
• Flow of 127 Nm3/h with 0.9 bar of suction; Discharge pressure of up to 310 bar;
• High resistance structure designed to resist the highest loads and to guarantee a long useful life;
• Low level of vibration and noise;
• Reliable and of simple maintenance, with very low down service time;
• Designed for heavy and continuous operations, the compressors are all tested before leaving the factory.

Control Panel

The control panel is based on a PLC, mounted on the skid, or at a distance, which controls and monitors the functioning of the compressor. The system detects, indicates and shuts down the compressor when abnormal conditions occur, such as low oil pressure, high discharge temperature, low and high suction pressure, high discharge pressure etc. Installation is explosion-proof and intrinsically safe.


Sound and Weather Protection Enclosure

The cabins provide protection against the weather and attenuate the noise generated by the compressor, maintaining them within the limits suitable for installation in urban areas.

• Sound insulation
• Weather protection
• Built in high resistance steel structure
• External instruments panel
• Gas detector at one point with alarm (optional)
• Lifting rings

Desenvolvido por GRUPO NOVOCOM